527 research outputs found

    The Deelen infrasound array for recording sonic booms and events of CTBT interest

    Get PDF
    The Seismology Division of the Royal Netherlands Meteorological Institute (KNMI) has build up expertise in infrasound measurements by investigating low frequency events in order to distinguish between seismic and sonic events. KNMI operates, amongst others, a sixteen element microbarometer array with an aperture of 1.5 km, the Deelen Infrasound Array (DIA). Sonic booms and events of Comprehensive Test Ban Treaty (CTBT) interest are recorded within the frequency range of 100 seconds and 40 Hertz. Recently, KNMI and Microflown Technologies B.V. started a collaboration concerning infrasound measurements. This paper reports the use of a novel sensor. The so-called Microflown [1] is an acoustic sensor, sensitive for frequencies from 0Hz up to 1kHz. The Microflown is developed at the University of Twente and commercialised by Microflown Technologies B.V [3]

    A novel technique for measuring the reflection coefficient of sound absorbing materials

    Get PDF
    A new method to measure the acoustic behaviour of sound absorbing material in an impedance tube is presented. The method makes use of a novel particle velocity sensor, the microflown, and a microphone. The so-called p·u method is compared to three other methods of which the two microphone technique is well known. It is shown that the combination of a microphone and a microflown provides direct information on the acoustic impedance, the sound intensity and the sound energy density. The experimental results are compared to the results obtained with the conventional impedance tube measurements. To be able to repeat the measurements in a reliable way a well described test sample with a quarter-wave resonator is used. Furthermore it is shown that the viscothermal effects on the wave propagation are important, i.e. for the quarter-wave resonator and to a lesser extent for the impedance tube itself

    A numerical study of a method for measuring the effective in situ sound absorption coefficient

    Get PDF
    The accuracy of a method [Wijnant et al., “Development and applica- tion of a new method for the in-situ measurement of sound absorption”, ISMA 31, Leuven, Belgium (2010).], for measurement of the effective area-averaged in situ sound absorption coefficient is investigated. Based on a local plane wave assump- tion, this method can be applied to sound fields for which a model is not available. Investigations were carried out by means of finite element simulations for a typical case. The results show that the method is a promising method for determining the effective area-averaged in situ sound absorption coefficient in complex sound fields

    A Three Dimensional Microflown

    Get PDF
    An integrated three dimensional acoustic particle velocity sensor is realized. The integration of multiple sensors on a single silicon die leads to improvements in terms of better a better reproducible sensor and a very small sensor to sensor distance allowing accurate single point measurements. Initial measurements performed show that three dimensional noise source finding is possible with this sensor

    Comparison of Two Methods for Measurement of Horn Input Impedance

    Get PDF
    Two methods to measure the acoustic input impedance of a horn are compared. First method measures standing wave patterns in a tube which is loaded by the horn. The input impedance is calculated from the position of the first minimum in the standing wave pattern, and the ratio of maximum and minimum sound pressure level in the tube. Secondly we applied a direct method. A novel flow sensor, the microflown, is used together with a pressure microphone, which are mounted in the throat of the horn. Results from both measurements are compared with simulated models

    Taenia solium Cysticercosis, Irian Jaya, Indonesia

    Get PDF
    Centers for Disease Control and Prevention, Toni, Wandra ; Akira, Ito ; Hiroshi, Yamasaki ; Thomas, Suroso ; Sri S. Margono, Emerging Infectious Diseases, 9(7), 2003, 884-885. publishe

    In-gas-cell laser ionization spectroscopy in the vicinity of 100Sn: Magnetic moments and mean-square charge radii of N=50-54 Ag

    Full text link
    In-gas-cell laser ionization spectroscopy studies on the neutron deficient 97-101Ag isotopes have been performed with the LISOL setup. Magnetic dipole moments and mean-square charge radii have been determined for the first time with the exception of 101Ag, which was found in good agreement with previous experimental values. The reported results allow tentatively assigning the spin of 97,99Ag to 9/2 and confirming the presence of an isomeric state in these two isotopes, whose collapsed hyperfine structure suggests a spin of 1/2 . The effect of the N=50 shell closure is not only manifested in the magnetic moments but also in the evolution of the mean-square charge radii of the isotopes investigated, in accordance with the spherical droplet model predictions
    • …
    corecore